5/6KW  2Mppts  Single Phase  Battery voltage 48V, up to 16 units can be paralleled

 

Technical Data

Model

 SUN-5K-SG03LP1-EU

SUN-6K-SG03LP1-EU

Battery Input Data

Battery Type

Lead-acid or Li-lon

Battery Voltage Range (V)

40~60

Max. Charging Current (A)

120

135

Max. Discharging Current (A)

120

135

External Temperature Sensor

Yes

Charging Curve

3 Stages / Equalization

Charging Strategy for Li-Ion Battery

Self-adaption to BMS

PV String Input Data

Max. DC Input Power (W)

6500

7800

Rated PV Input Voltage (V)

370 (125~500)

Start-up Voltage (V)

125

MPPT Voltage Range (V)

150-425

Full Load DC Voltage Range (V)

300-425

PV Input Current (A)

13+13

Max. PV ISC(A)

17+17

No.of MPP Trackers

2

No.of Strings per MPP Tracker

1

AC Output Data

Rated AC Output and UPS Power (W)

5000

6000

Max. AC Output Power (W)

5500

6600

AC Output Rated Current (A)

22.7/21.7

27.3/26. 1

Max. AC Current (A)

25/23.9

30/28.7

Max. Continuous AC Passthrough (A)

     35

40

Peak Power (off grid)

 2 time of rated power, 10 S

Power Factor

   0.8 leading to 0.8 lagging

Output Frequency and Voltage

 50/60Hz; L/N/PE  220/230Vac (single phase)

Grid Type

       Single Phase

Total Harmonic Distortion (THD)

    <3% (of nominal power)

DC current injection

   <0.5% In

Efficiency

Max. Efficiency

97.60%

Euro Efficiency

96.50%

MPPT Efficiency

99.90%

Protection

Integrated

PV Input Lightning Protection, Anti-islanding Protection, PV String Input Reverse Polarity Protection,
Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection,
Output Shorted Protection, Surge protection

Output Over Voltage Protection

DC Type II/AC Type III

Certifications and Standards

Grid Regulation

VDE4105, IEC61727/62116, VDE0126, AS4777.2, CEI 0 21, EN50549- 1,
G98, G99, C10- 11, UNE217002, NBR16149/NBR16150

Safety EMC / Standard

IEC/EN 61000-6- 1/2/3/4, IEC/EN 62109- 1, IEC/EN 62109-2

General Data

Operating Temperature Range (C)

-40~60C, >45C derating

Cooling

Natural cooling

Noise (dB)

<30 dB

Communication with BMS

RS485; CAN

Weight (kg)

20.5

Size (mm)

330W x 580H x232D

Protection Degree

IP65

 Installation Style

Wall-mounted

Warranty

5 years

 

Application

Pitched roof

Flat roof

Roof Slope

Up to 60°

Fixed, 10-15°,15-30°,30-60°/Up to 45°

Building height

Up to 20m

Up to 20m

Roof cladding

Suitable for most types of cladding

/

Recommended wind speed

Up to 79.2m/s ( wind region D )

Up to 79.2m/s ( wind region C )

PV module

Framed, unframed

Framed

Module orientation

Landscape, portrait

Landscape, portrait

Material

Anodized aluminum 6005 T6 stainless steel 304

Anodized aluminum 6005 T6, stainless steel 304, 410

Standard

AS/NZ1170.2:2011, JIS C 8955:2011